3 resultados para Aquatic environment

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die Ziele der vorliegenden Arbeit waren 1) die Entwicklung und Validierung von sensitiven und substanz-spezifischen Methoden für die quantitative Bestimmung von anionischen, nichtionischen und amphoteren Tensiden und deren Metaboliten in wässrigen Umweltproben unter Einsatz leistungsfähiger, massenspektrometrischer Analysengeräte,2) die Gewinnung von aeroben, polaren Abbauprodukten aus Tensiden in einem die realen Umweltbedingungen simulierenden Labor-Festbettbioreaktor (FBBR), dessen Biozönose oberflächenwasserbürtig war,3) zur Aufklärung des Abbaumechanismus von Tensiden neue, in 2) gewonnene Metabolite zu identifizieren und massenspektrometrisch zu charakterisieren ebenso wie den Primärabbau und den weiteren Abbau zu verfolgen,4) durch quantitative Untersuchungen von Tensiden und deren Abbauprodukten in Abwasser und Oberflächenwasser Informationen zu ihrem Eintrag und Verhalten bei unterschiedlichen hydrologischen und klimatischen Bedingungen zu erhalten,5) das Verhalten von persistenten Tensidmetaboliten in Wasserwerken, die belastetes Oberflächenwasser aufbereiten, zu untersuchen und deren Vorkommen im Trinkwasser zu bestimmen,6) mögliche Schadwirkungen von neu entdeckten Metabolite mittels ökotoxikologischer Biotests abzuschätzen,7) durch Vergleich der Felddaten mit den Ergebnissen der Laborversuche die Umweltrelevanz der Abbaustudien zu belegen. Die Auswahl der untersuchten Verbindungen erfolgte unter Berücksichtigung ihres Produktionsvolumens und der Neuheit auf dem Tensidmarkt. Sie umfasste die Waschmittelinhaltsstoffe lineare Alkylbenzol-sulfonate (LAS), welches das Tensid mit der höchsten Produktionsmenge darstellte, die beiden nichtionischen Tenside Alkylglucamide (AG) und Alkylpolyglucoside (APG), ebenso wie das amphotere Tensid Cocamidopropylbetain (CAPB). Außerdem wurde der polymere Farbübertragungsinhibitor Polyvinylpyrrolidon (PVP) untersucht.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous and found in the atmosphere, aquatic environment, sediments and soils. For environmental risk assessments and the allocation of the polluter it is important to know the PAH sources. PAH contamination sites are usually the result of anthropogenic processes. Three major sources are known: i) petroleum, including crude oil and its refined products and coals (petrogenic PAHs), ii) burning of organic matter (pyrogenic PAHs) and iii) transformation products of natural organic precursors present in the environment (diagenetic processes). In one case elevated PAH concentrations were found in river bank soils when building a retention area along the Mosel River. The source of the PAHs in this area was unclear and required the investigation of possible sources. To evaluate the PAH distribution along the Mosel River, a section of ~ 160 km along the river and a short section along the Saar River were investigated within this study. Concentrations of the Σ16 EPA PAHs were as high as 81 mg kg-1 dry weight (dw). Additionally, coal particles were identified in some soils, which originated from mining activities in the Saarland region. PAH distribution patterns of the 16 EPA PAHs suggest a mainly pyrogenic origin and in some cases a mixture of pyrogenic and petrogenic origin. For a comprehensive investigation five sampling sites were selected. Two sites were located before the confluence of the Mosel and Saar River, one site at the confluence and two sites after the confluence. The examination included typical forensic methods such as PAH distribution patterns of 45 PAHs (including alkylated PAHs), calculation of PAH ratios, determination of PAH alkyl homologues, n-alkanes, principal component analysis (PCA) and coal petrography. The results revealed a mainly pyrogenic source at sampling sites before the confluence of the two rivers. At and after the confluence, a mixture of pyrogenic and petrogenic inputs were present. With the help of coal petrography, coal derived particles could be identified in these soils. Therefore, coal was suggested to be the petrogenic source. It could be shown that sites with diffuse sources of contaminants, like the bank soils of the Mosel River, are difficult to characterize. As previously mentioned for detailed source identifications, the use of various forensic methods is essential. Determination of PAH alkyl homologue series, biomarkers and isotopes are often recommended. Source identification was evaluated using three different methods (i.e. PAH distribution patterns of an extended PAH spectrum, PAH ratios and analyses of n-alkanes). It was assessed if these methods were sufficient for the initial steps in identifying sources of PAHs in selected samples, and if they could be used for decision-making purposes. Point- and non-point sources were identified by applying the three methods and it could be shown that these relatively simple methods are sufficient in determining the primary source. In a last step of this study two soils (one before the confluence of the Mosel and Saar rivers and one after the confluence), and one sediment of the Mosel River were evaluated by investigating the mutagenic potential of the soils and the sediment with a fluctuation version of the Ames-test. The study showed that coal bearing soils at the Mosel River do not exhibit a greater mutagenic potential than other soils or sediments without coal particles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Vancomycin-resistente Enterokokken (VRE) treten als Erreger von nosokomialen Infektionen immer häufiger auf und schränken die Therapiemöglichkeiten deutlich ein. In den eigenen Untersuchungen wurde das Vorkommen von Vancomycin-resistenten Enterococcus faecium (VREf) bei Patienten und in der aquatischen Umwelt (Abwasser und Oberflächenwasser) über einen Zeitraum von sechs Jahren (2004 bis 2009) untersucht. Eine Genotypisierung mittels Pulsfeld-Gelelektrophorese (PFGE) von 294 VREf sollte Aufschluss über genetische Verwandtschaften geben. rnEs konnte gezeigt werden, dass VREf in der aquatischen Umwelt weit verbreitet sind. In Bezug auf ihre genetische Diversität zeigten sie ein breites Spektrum an Variabilität. Ebenso konnte im zeitlichen Auftreten von VREf-Typen eine Dynamik beobachtet werden, wodurch sich Veränderungen der Population mit zeitlichem Wechsel ergaben. Enge Verwandtschaften zwischen VREf von Patienten und VREf aus der aquatischen Umwelt konnten nachgewiesen werden. Für zwei VREf gelang der Nachweis des Eintrags in die aquatische Umwelt, von Patienten aus dem Krankenhaus als Eintragsquelle ausgehend, während Zeiten eines Ausbruchs mit nosokomialen Erregern auf den Stationen. rnZusätzlich zur VREf-Population wurden außerdem die Wirkungsweise und Effizienz einer Elektroimpulsanlage untersucht, um ein zukunftsorientiertes Verfahren zur Desinfektion von bakteriell belasteten Abwässern zu entwickeln. Weiterführend wurde getestet, inwiefern sich verschiedene klinisch relevante VREf durch ein gepulstes elektrisches Feld abtöten lassen. rnEs konnte gezeigt werden, dass das synergistische Zusammenwirken des elektrischen Feldes und der Prozesstemperatur die Höhe der Keimzahlreduktion der Enterokokken beeinflussen. Dabei wurde eine isolatabhängige Elektroresistenz der VREf gegenüber gepulsten elektrischen Feldern bewiesen. Die untersuchten VREf ließen sich, im Gegensatz zu einem Vancomycin-sensiblen Stamm, nicht effizient durch die Elektroimpulsanlage abtöten, was den praktischen Einsatz einer solchen Elektroimpulsanlage als wirkungsvolles Desinfektionsverfahren in Frage stellte.